Home>mall>Electronics
0Hoffi

GM328A Transistor Tester Diode Capacitance ESR Voltage Frequency Meter PWM Square Waving Signal Generator Soldering

3.9
★★★★★
38
$12.59 /$15.36
  • *Name:

  • *Email:

  • *Phone:

  • *Quantity:

  • *Content:

  • Attachment:

    Supports JPG, JPEG, PNG, PDF, EXCEL, WORD, RAR, ZIP, 7z formats

$8.39 /$15.36

Talu Diogel wedi'i Warantu

Rhodd Am Ddim
Rhodd am ddim gydag unrhyw bryniad
Polisi Cludo
Cludo safonol am ddim ar archebion dros $9.9
Polisi Dychwelyd
Bydd eitemau a ddychwelir yn cael eu derbyn o fewn 40 diwrnod o'r dyddiad o dderbyn y nwyddau. Ni ellir dychwelyd na chyfnewid eitemau wedi'u cyfaddasu. Ni ellir dychwelyd eitemau a brynwyd gyda cherdyn rhodd e; dim ond cyfnewid y gellir eu gwneud.

Rhodd Am Ddim

Croeso i Roymall, eich gwefan broffesiynol ar gyfer prynu rhoddion siopau adran premium. Rydym yn gwerthfawrogi ac yn gwerthfawrogi eich cefnogaeth, ac rydym am fynegi ein diolch trwy ychwanegu cyffro ychwanegol at eich pryniadau. Pan fyddwch yn siopa gyda ni, nid yn unig y byddwch yn cael mwynhau cynnyrch o ansawdd uchel sy'n gwella eich ffordd o fyw, ond byddwch hefyd yn derbyn rhodd am ddim gyda phob archeb a wnewch. Barod i archwilio ein casgliad a dod o hyd i'ch rhoddion perffaith? Poriwch ein dewis o eitemau siop adran premium, gwneud eich archeb, ac edrych ymlaen at y cyffro o gael eich rhodd am ddim yn dod ochr yn ochr â'ch pryniad.

Polisi Cludo

Byddwn yn gweithio'n galed i gyflwyno eitemau atoch ar ôl derbyn eich archebion a sicrhau eu bod yn cyrraedd yn ddiogel. Bydd manylion cludo yn cael eu darparu yn eich e-bost cadarnhau.Yn y rhan fwyaf o achosion, mae archebion yn cael eu prosesu o fewn 2 ddiwrnod.O dan amgylchiadau arbennig, bydd yn cael ei oedi fel a ganlyn: Pan fyddwch yn gwneud archeb ar ddydd Sadwrn, dydd Sul neu wyliau cyhoeddus, bydd yn cael ei oedi am 2 ddiwrnod..Yn nodweddiadol, mae angen 5-7 diwrnod gwaith (dydd Llun i ddydd Gwener) heb gael eu heffeithio gan oedi hedfan neu ffactorau amgylcheddol eraill..Gan fod ein gwasanaeth cludo yn fyd-eang, bydd yr amseroedd cludo yn dibynnu ar eich lleoliad, felly gall gymryd ychydig o amser ac, os gwelwch yn dda, aros yn amyneddgar os ydych yn ardaloedd neu wledydd anghysbell.

1. Polisi Dychwelyd a Chyfnewid

Dim ond eitemau a brynwyd ar roymall.com y byddwn yn eu derbyn. Os ydych yn prynu gan ein dosbarthwyr lleol neu fanwerthwyr eraill, ni allwch eu dychwelyd atom ni. Ni fydd eitemau gwerthu terfynol neu roddion am ddim yn cael eu derbyn ar gyfer dychwelyd. I fod yn gymwys i'w dychwelyd, rhaid i'ch eitem fod yn heb ei defnyddio ac yn yr un cyflwr ag yr oedd pan gawsoch hi. Rhaid iddi hefyd fod yn y pecyn gwreiddiol.Ar ôl derbyn cyfarwyddiadau dychwelyd gennym, os gwelwch yn dda, pecynwch eich eitemau a ddychwelwyd a gollwng eich pecyn yn y swyddfa bost leol neu gludwr arall.
Byddwn yn prosesu'ch eitem a ddychwelwyd neu a gyfnewidir o fewn 3-5 diwrnod gwaith ar ôl iddo gyrraedd. Bydd yr ad-daliad yn cael ei brosesu a'i gredyd yn awtomatig i'ch dull talu gwreiddiol.Ni ellir derbyn dychweliadau na chyfnewidiadau os cafodd y cynnyrch ei gynhyrchu'n bersonol, gan gynnwys maint wedi'i gyfaddasu, lliw wedi'i gyfaddasu neu argraff wedi'i gyfaddasu.Angen mwy o help, os gwelwch yn dda, cysylltwch â ni. service@roymall.com neu Whatsapp: +8619359849471

2.Polisi Ad-dalu

Byddwch yn cael ad-daliad llawn neu gredyd siop 100% ar ôl i ni dderbyn y pecyn a ddychwelwyd a'i wirio. Bydd yr ad-daliad yn cael ei brosesu a'i gredyd yn awtomatig i'ch dull talu gwreiddiol. Sylwch nad yw costau cludo ac unrhyw drethi neu ffi yn cael eu had-dalu. Nid yw'r costau cludo ychwanegol yn cael eu had-dalu ar ôl i'r pecyn gael ei anfon. Rydych chi'n gyfrifol am dalu'r ffioedd hyn, ac ni allwn eu hosgoi na'u had-dalu, hyd yn oed os yw'r archeb yn cael ei dychwelyd atom ni.Ar ôl derbyn a chadarnhau'ch eitem a ddychwelwyd, byddwn yn anfon e-bost atoch i'ch hysbysu ein bod wedi derbyn eich eitem a ddychwelwyd. Byddwn hefyd yn eich hysbysu am gymeradwyo neu wrthod eich ad-daliad.Os oes gennych unrhyw broblemau ynghylch y broses ad-dalu, os gwelwch yn dda, cysylltwch â ni. service@roymall.com neu Whatsapp: +8619359849471
Specification:
Input voltage: DC5V
Operating voltage: about 30mA
Transistor tester control
The tester is controlled by a rotary encoder switch.
The rotary encoder switch can have a total of 6 operations, short press, long press, left turn, right turn, press left turn, press right turn.
Press once in the off state to turn on the power and start the test.
After a test is completed, if no device is detected. Long press the switch or rotate the switch left and right to enter the function menu. After entering the function menu, the left or right switch can select up and down the menu item. To enter a function item, press the switch once. When you need to exit from a function, hold down the switch.


Features:
1. Digital liquid crystal display, easy reading, can display the measured data and graphics
2. Rotary switch control, easy to use button measurement
3. Long press the test button to exit the frequency measurement function. The frequency measurement range is from 1Hz to above 1MHz. When the measured frequency is lower than 25KHz, the cycle is displayed
4. Square waving generator, there are multiple levels of squarewaving frequency optional, left or right rotation test button to switch different square waving frequency, long press the test button to exit the squarewaving generator
5. Pulse signal generator, left or right rotation test button to adjust pulse duty cycle from 1% to 99%. Long press the test button to exit the pulse generator
6. Use 5V Type-c power supply interface for power supply, customers can also solder 9V battery interface for power supply
7. Automatic shutdown, shutdown current is only about 20nA

Note:
Before testing the capacitor, discharge the capacitor first, and then insert the test base for measurement, otherwise the microcontroller of the tester may be damaged.


Package includes:
1x GM328A transistor tester


Calibration:
1. Tester calibration is used to eliminate the error of its own components, so that the final test results are more accurate. Calibration is divided into rapid calibration and full-function calibration.
2. Operation method of quick calibration: short connect the three test points TP1, TP2 and TP3 with wires, and then press the test button, while paying attention to the screen. The screen color will change to white text on black background, and the prompt "Selftest mode.. ?" After that, press the test button to enter the rapid calibration process; If the message "Selftest mode.. ?" After that, if there is no key within 2 seconds, a normal test process will be carried out. Finally, the resistance values of the wires at the three test points of TP1, TP2 and TP3 are displayed. Once you go through the quick calibration process, you"ll see some data on the screen, just ignore it. Wait until a blinking string appears on the screen"Isolate the Probes!" After that, remove the short wires of TP1, TP2, and TP3. The quick calibration is completed until the string "Test End" appears on the screen. For the first calibration, use full function calibration.
3. Full function calibration needs to be accessed from the function menu, and an additional 220nf capacitor is required. Full-function calibration performs a more comprehensive calibration process and takes longer. Once in the features menu, rotate the test button to the menu item "Selftest", then press the test button to enter the fully functional calibration process, with the blinking string "short Probes!" popping up on the screen first. As with the quick calibration, the three test points are shorted with wires and wait for the calibration process to occur, with the string "isolate Probes!" flashing on the screen. , remove the short in three test points lead, continue to wait for the calibration process, the screen string "1 - | | - 3 & gt; For 100nf, install the 220nf capacitor on the test points TP1 and TP3. Wait until the screen prompts "Test End" and the full-function calibration process is complete.

GM328A Transistor Tester Diode Capacitance ESR Voltage Frequency Meter PWM Square Waving Signal Generator Soldering

GM328A Transistor Tester Diode Capacitance ESR Voltage Frequency Meter PWM Square Waving Signal Generator Soldering

GM328A Transistor Tester Diode Capacitance ESR Voltage Frequency Meter PWM Square Waving Signal Generator Soldering

GM328A Transistor Tester Diode Capacitance ESR Voltage Frequency Meter PWM Square Waving Signal Generator Soldering

GM328A Transistor Tester Diode Capacitance ESR Voltage Frequency Meter PWM Square Waving Signal Generator Soldering

GM328A Transistor Tester Diode Capacitance ESR Voltage Frequency Meter PWM Square Waving Signal Generator Soldering

GM328A Transistor Tester Diode Capacitance ESR Voltage Frequency Meter PWM Square Waving Signal Generator Soldering

GM328A Transistor Tester Diode Capacitance ESR Voltage Frequency Meter PWM Square Waving Signal Generator Soldering

Fy Nghart Cart (12)
Fy Ffefrynnau Fy Ffefrynnau (0)